TECHNICAL DETAILS
 
POWER VENSYS 77 VENSYS 82
Rated power: 1500 kW 1500 kW
Rated Wind Speed(10 min. mean) approx. 13 m/s approx 10.3 m/s
Cut-out wind speed(10 min. mean) 22 m/s 22 m/s
Survival wind speed: 52.5 m/s 52.5 m/s
 
ROTOR
Diameter: 77 82
Swept area: 4634 sq.m
5258 sq.m
Speed range (variable) 9 to 17.3 rpm 9 to 17.3 rpm
 
TOWER AND FOUNDATION
Hub height: 85 m 85 m
Design: Four sections Four sections
Foundation type: Floating foundation Floating foundation
 
CONTROL AND SAFETY SYSTEMS
Control of output Pitch Pitch
Speed control Variable, microprocessor-controlled speed
Variable, microprocessor-controlled speed
Primary brake system Individual blade pitch control for each blade Individual blade pitch control for each blade
Remote control Dial –up connection, visualization via web-browser Dial –up connection, visualization via web-browser
 
TYPE CLASSES
Wind turbine type class: IEC III A IEC III A


*Specifications are subject to change